Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 61935

3 recalled-product records grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
May 16, 2012
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
Boston Scientific Corporation

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

3 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 3

Boston Scientific Profile Single-Use Pediatric Snare 11mm UPN Outer Box M00562531 Inner Pouch: M00562530 , The single-use Profile Polypectomy Snare consists of a flexible wire cable loop which can be extended and retracted from the snare's flexible outer sheath using a three-ring handle. When passed through an endoscope and activated, the snare delivers a monopolar electrical current to cut and cauterize tissue with the loop

Z-1850-2012
Recall number
Z-1850-2012
Initiated
May 16, 2012
Classification
Class II
Status
Terminated
Quantity
2760 units

App-derived interpretation

Unknown reason.no_named_rule · v1.0.0
Difficulty in extending snare loop from the catheter

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Process control

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Difficulty in extending snare loop from the catheter

Code information

Lot Numbers: 14951476, 14951479, 14987882,15068203

Distribution pattern

Worldwide Distribution - USA (nationwide) and the countries of Canada, Australia, Austria, Belgium, France, GB, Germany, Italy, Netherlands, Qatar, Spain, Sweden, and Switzerland

device · product 2 of 3

Boston Scientific Profile Single-Use Pediatric Snare 13mm UPN Outer Box: M00562551 Inner Pouch: M00562550 The single-use Profile Polypectomy Snare consists of a flexible wire cable loop which can be extended and retracted from the snare's flexible outer sheath using a three-ring handle. When passed through an endoscope and activated, the snare delivers a monopolar electrical current to cut and cauterize tissue with the loop

Z-1851-2012
Recall number
Z-1851-2012
Initiated
May 16, 2012
Classification
Class II
Status
Terminated
Quantity
1970 units

App-derived interpretation

Unknown reason.no_named_rule · v1.0.0
Difficulty in extending snare loop from the catheter

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Process control

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Difficulty in extending snare loop from the catheter

Code information

Lot Numbers: 14951482, 14951484, 15068143

Distribution pattern

Worldwide Distribution - USA (nationwide) and the countries of Canada, Australia, Austria, Belgium, France, GB, Germany, Italy, Netherlands, Qatar, Spain, Sweden, and Switzerland

device · product 3 of 3

Boston Scientific Profile Single-Use Pediatric Snare 27mm UPN Outer Box: M00562571 Inner Pouch: M00562570 The single-use Profile Polypectomy Snare consists of a flexible wire cable loop which can be extended and retracted from the snare's flexible outer sheath using a three-ring handle. When passed through an endoscope and activated, the snare delivers a monopolar electrical current to cut and cauterize tissue with the loop

Z-1852-2012
Recall number
Z-1852-2012
Initiated
May 16, 2012
Classification
Class II
Status
Terminated
Quantity
1340 units

App-derived interpretation

Unknown reason.no_named_rule · v1.0.0
Difficulty in extending snare loop from the catheter

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Process control

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Difficulty in extending snare loop from the catheter

Code information

Lot Number: 14974048

Distribution pattern