Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 64316

1 recalled-product record grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
February 12, 2013
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
Oculus Innovative Sciences Inc

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 1

Atrapro Antipruritic Hydrogel, 1.5 oz gel tube, 4 Net wt/ 1.5 oz.. RX only, Professional Sample, Not for Sale. Pre-printed tube: MS31071, Shelf carton: PL51091-08 Atrapro Antipruritic HydroGel is indicated to manage and relieve the burning, itching and pain experienced with various types of dermatoses, including radiation dermatitis and atopic dermatitis.

Z-0890-2013
Recall number
Z-0890-2013
Initiated
February 12, 2013
Classification
Class II
Status
Terminated
Quantity
56,566 1.5 oz tubes

App-derived interpretation

Potency or specification failure reason.potency_specification_failure · v1.0.0
Out of specification

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Incorrect or no expiration date

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Out of specification result - stability test failure of free available chlorine (FAC) which functions as a preservative for the hydrogel. The 13 month test result obtained was 4 ppm FAC and the stability specification is >10 ppm FAC.

Code information

Lot 12A0012, Exp 2/2013; Lot 12A0013, Exp 2/2013: Lot 12A1116, Exp 2.2013; Lot 12A1119, Exp 2/2013; Lot 12B1144, Exp 3/2013; Lot 12B1148, Exp 3/2013; Lot 12C1157, Exp 4/2013; Lot 12E190. Exp 6/2013; Lot 12E194, Exp 6/2013; Lot 12E198, Exp 6/2013; Lot 12E202. Exp 6/2013; Lot 12E208, Exp 6/2013; Lot 12E211, Exp 6/2013.

Distribution pattern

Nationwide Distribution - One distributor in PA