Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 66859

1 recalled-product record grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
October 24, 2013
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
Kimberly-Clark Corporation

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 1

Kimberly-Clark Single Shot Epidural Pain Management Trays containing the BD LOR Syringe (BD Code 405198) Product Usage: The device is designed to provide regional anesthesia. The device may contain syringes, needles and drugs

Z-0518-2014
Recall number
Z-0518-2014
Initiated
October 24, 2013
Classification
Class II
Status
Terminated
Quantity
389,300 units

App-derived interpretation

Unknown reason.no_named_rule · v1.0.0
Kimberly-Clark Single Shot Epidural Pain Management Trays contain the BD 7 mL Epilor plastic Luer-Lok LOR Syringes under recall by Becton Dickinson (BD) because the product may stall or stick when traveling within the barrel of the syringe.

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Component design/selection

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Kimberly-Clark Single Shot Epidural Pain Management Trays contain the BD 7 mL Epilor plastic Luer-Lok LOR Syringes under recall by Becton Dickinson (BD) because the product may stall or stick when traveling within the barrel of the syringe.

Code information

Lot numbers: 181024, 181129 181217, 181221, 181231, 182022, 182058, 182101, 182108, 182131, 182222, 182223, 182263, 182265, 182289, 182293, 182301, 182315, 181A074, 181A94, 181A154, 181A177, 181A286, 181A289, 181A369, 182A002, 182A005, 182A012, 182A055, 182A056, 182A057, 182A064, 182A074, 182A075/182A78, 182A085, 182090, 182A142, 182AA144, 182A151, 182A155, 182A178, 182A194, 182A196, 182A198, 182A202, 182A204, 182A212, 182A216 and 189A001 (syringe).

Distribution pattern

U.S. Nationwide Distribution