Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 67092

2 recalled-product records grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
November 21, 2013
Product types
Drug
Classifications
Class I
Statuses
Terminated
Recalling firm wording
Baxter Healthcare Corp.

Dossier provenance

Source snapshots represented here

  • openFDA Drug Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

2 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

drug · product 1 of 2

5% Dextrose Injection, USP, 100 mL Single dose VIAFLEX plastic containers, Rx only, Baxter Healthcare Corporation, Deerfield, IL 60015 USA, Product code 2B0089, NDC 0338-0017-38.

D-1162-2014
Recall number
D-1162-2014
Initiated
November 21, 2013
Classification
Class I
Status
Terminated
Recalling firm
Baxter Healthcare Corp.
Quantity
105,216 containers

App-derived interpretation

Foreign material or chemical contamination reason.foreign_material_chemical_contamination · v1.0.0
particulate matter

These labels are deterministic app interpretations, not FDA categories.

Inspect official wording and provenance

Reason for recall

Presence of Paticulate Matter; Baxter is issuing a voluntary recall for these IV solutions due to particulate matter found in the solution identified as polyester and cotton fibers, adhesive-like mixture, polyacetal particles, thermally degraded PVC, black polypropylene and human hair embedded in the plastic bag

Code information

Lot #: P285288, Exp 11/13

Distribution pattern

Nationwide, Puerto Rico, Singapore, Saudi Arabia and United Arab Emirates.

drug · product 2 of 2

0.9% Sodium Chloride Injection, USP, packaged in a) 50 mL Single dose VIAFLEX plastic containers (Product code 2B1308, NDC 0338-0049-31) and b) 100 mL Single dose VIAFLEX plastic containers (Product code 2B1302, NDC 0338-0049-18) and (Product code 2B1309, NDC 0338-0049-38), Rx only, Baxter Healthcare Corporation, Deerfield, IL 60015 USA.

D-1163-2014
Recall number
D-1163-2014
Initiated
November 21, 2013
Classification
Class I
Status
Terminated
Recalling firm
Baxter Healthcare Corp.
Quantity
716,544 containers

App-derived interpretation

Foreign material or chemical contamination reason.foreign_material_chemical_contamination · v1.0.0
Particulate Matter

These labels are deterministic app interpretations, not FDA categories.

Inspect official wording and provenance

Reason for recall

Presence of Particulate Matter: Baxter is issuing a voluntary recall for these IV solutions due to particulate matter found in the solution identified as polyester and cotton fibers, adhesive-like mixture, polyacetal particles, thermally degraded PVC, black polypropylene and human hair embedded in the plastic bag

Code information

Lot #: a) P297283, Exp 08/14; b) P292326, Exp 04/14; P293993, Exp 05/14; and P293514, Exp 04/14

Distribution pattern

Nationwide, Puerto Rico, Singapore, Saudi Arabia and United Arab Emirates.