Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 68954

1 recalled-product record grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
July 30, 2014
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
Integra York PA, Inc

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 1

Integra Container Lid, ¿¿ Size, Red; Container Lid, ¿¿ Size, Blue; Container Lid, ¿¿ Size, Red; Container Lid, ¿¿ Size, Gold; Container Lid, ¿¿ Size, Green; Container Lid, Full Size, Blue; Container Lid, Full Size, Red Catalogue Numbers: 730422, 730521, 730522, 730523, 730524, 730621, 730622 The Integra Sterilization Container is intended for use in hospitals and healthcare facilities to contain other medical devices that are to be steam sterilized (autoclaved) by the facility prior to use. Sterilized devices may be stored and transferred within the facility in the container per the healthcare facilities protocols. Integra provides these items to users as either as a tray and lid combination, just a tray, or just a lid.

Z-2624-2014
Recall number
Z-2624-2014
Initiated
July 30, 2014
Classification
Class II
Status
Terminated
Recalling firm
Integra York PA, Inc
Quantity
84

App-derived interpretation

Unknown reason.no_named_rule · v1.0.0
Integra LifeSciences has identified through an internal investigation that some colored lids for Integra container systems were not yet cleared by the FDA for sale and were inadvertently distributed.

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Employee error

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Integra LifeSciences has identified through an internal investigation that some colored lids for Integra container systems were not yet cleared by the FDA for sale and were inadvertently distributed.

Code information

Container Lid, ¿ Size, Red; Container Lid, ¿ Size, Blue; Container Lid, ¿ Size, Red; Container Lid, ¿ Size, Gold; Container Lid, ¿ Size, Green; Container Lid, Full Size, Blue; Container Lid, Full Size, Red Catalogue Numbers: 730422, 730521, 730522, 730523, 730524, 730621, 730622

Distribution pattern

US only to one repacker/relabeler and three medical facilities. The relabeler was identified as: KLS Martin, 11201 St. Johns Industrial Parkway S, Jacksonville, FL 32246 (904) 641-7746