Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 71815

1 recalled-product record grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
July 20, 2015
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
Trilliant Surgical Ltd.

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 1

Concave Reamer Head, 16 mm; Concave Reamer Head, 18 mm; Concave Reamer Head, 20 mm; Concave Reamer Head 22 mm; Convex Reamer Head, 16 mm; Convex Reamer Head, 18 mm; Convex Reamer Head 20 mm; Convex Reamer Head 22 mm, used with Gridlock Plating system, for use in trauma and reconstructive procedures in small bones.

Z-2456-2015
Recall number
Z-2456-2015
Initiated
July 20, 2015
Classification
Class II
Status
Terminated
Recalling firm
Trilliant Surgical Ltd.
Quantity
638 units

App-derived interpretation

Unknown reason.no_named_rule · v1.0.0
The cannulation of the Concave and Convex Reamer Heads may be too small to allow the Guide Pin to freely pass through.

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Component design/selection

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

The cannulation of the Concave and Convex Reamer Heads may be too small to allow the Guide Pin to freely pass through.

Code information

TSL000145, TSL000162, TSL000699, TSL000146, TSL000163, TSL000700, TSL00147, TSL000164, TSL000701, TSL000702, TSL000148, TSL000165, TSL000706, TSL000149, TSL000166, TSL000688, TSL000150, TSL000167, TSL000707, TSL000708

Distribution pattern

Nationwide throughout the US