Timeline bucket
August 10, 2016
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
Blackrock Microsystems, LLC

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

2 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 2

Neural Signal Amplifier. Part Numbers: 4208, 5703, 5749, 5748, 5747. Product Usage: The Blackrock NeuroPort Biopotential Signal Processing System supports recording, processing and display of biopotential signals from user supplied electrodes. Biopotential signals include: Electrocorticography (ECoG), electroencephalography (EEG), electromyography (EMG), electrocardiography (ECG), electrooculography (EOG) and Evoked Potential (EP)

Z-2763-2016
Recall number
Z-2763-2016
Initiated
August 10, 2016
Classification
Class II
Status
Terminated
Quantity
81 total amplifiers

App-derived interpretation

Labeling or packaging reason.labeling_packaging · v1.0.0
incorrectly labeled

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Labeling False and Misleading

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Blackrock Microsystems, LLC announces a voluntary field action for the Blackrock NeuroPort Biopotential Signal Processing System because the Neural Signal Amplifier and the Patient Cable are incorrectly labeled as Type CF Applied Parts.

Code information

Part Number 4208: Serial Numbers 0014 and 0016 Only Part Number 5703: All Serial Numbers Part Number 5748: All Serial Numbers Part Number 5747: All Serial Numbers

Distribution pattern

Worldwide Distribution - US Nationwide and Canada,

device · product 2 of 2

Patient Cable. Part Numbers: 4460, 6735. Sterile within Chipboard Boxes within corrugated cartons. Product Usage: The Blackrock NeuroPort Biopotential Signal Processing System supports recording, processing and display of biopotential signals from user supplied electrodes. Biopotential signals include: Electrocorticography (ECoG), electroencephalography (EEG), electromyography (EMG), electrocardiography (ECG), electrooculography (EOG) and Evoked Potential (EP)

Z-2764-2016
Recall number
Z-2764-2016
Initiated
August 10, 2016
Classification
Class II
Status
Terminated
Quantity
120 total cables

App-derived interpretation

Labeling or packaging reason.labeling_packaging · v1.0.0
incorrectly labeled

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Labeling False and Misleading

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Blackrock Microsystems, LLC announces a voluntary field action for the Blackrock NeuroPort Biopotential Signal Processing System because the Neural Signal Amplifier and the Patient Cable are incorrectly labeled as Type CF Applied Parts.

Code information

Part Number 4460: All Serial Numbers Part Number 6735: All Serial Numbers

Distribution pattern

Worldwide Distribution - US Nationwide and Canada,