Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 75365

1 recalled-product record grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
October 05, 2016
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
C.R. Bard, Inc.

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 1

Magic3 Antibacterial Hydrophilic Intermittent Catheter, Male 14 Fr. (30/Box), Sterile Product Usage: The catheter is an all silicone, single lumen, drainage tube with drainage eyes at the proximal end and a tapered funnel at the distal end. The outer surface of the catheter has an antibacterial and hydrophilic coating which binds water molecules to the surface creating a smooth lubricating film. It is packaged with a water sachet that is manually burst to hydrate the catheter coating at time of use. The catheters are packaged in a film-to-film pouch and are sterilized by electron beam irradiation and are distributed as a single use device. The catheter is intended for urinary bladder drainage in adult males and females requiring catheterization for management of incontinence, voiding dysfunction and surgical procedures. Efficacy of the catheter in preventing urinary tract infection during intermittent use has not been established. The device is not intended to be used as a treatment for active urinary tract infection. For urological use only; urinary catheters are intended for use for bladder management including urine drainage, collection and measurement. The devices are passed to the urinary bladder via the urethra.

Z-0600-2017
Recall number
Z-0600-2017
Initiated
October 05, 2016
Classification
Class II
Status
Terminated
Recalling firm
C.R. Bard, Inc.
Quantity
10,290 units

App-derived interpretation

Labeling or packaging reason.labeling_packaging · v1.0.0
Misbranding

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Mixed-up of materials/components

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Misbranding; the product labeled as an Antibacterial Hydrophilic Intermittent Catheter, is instead an Antibacterial Intermittent Catheter (no Hydrophilic Coating).

Code information

Product Code: 53514, Lot number: 53622813, Exp. Date: 30Sep2017.

Distribution pattern

US Nationwide Distribution in the states of: CA, FL, IL, IN, MN, MO, NC, NJ, NY, OH, OK, PA, TX and UT.