Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 77956

2 recalled-product records grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
August 22, 2017
Product types
Drug
Classifications
Class II
Statuses
Terminated
Recalling firm wording
Pfizer Inc.

Dossier provenance

Source snapshots represented here

  • openFDA Drug Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

2 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

drug · product 1 of 2

HYDROmorphone HCl Injection, USP, 2 mg/mL, 1mL Single-use vial, packaged in cartons of 25 vials, Rx only, Hospira, Inc., Lake Forest, IL 60045 USA, NDC 0409-3365-11 (carton) and 0409-3365-01(vial)

D-1167-2017
Recall number
D-1167-2017
Initiated
August 22, 2017
Classification
Class II
Status
Terminated
Recalling firm
Pfizer Inc.
Quantity
115,370 vials

App-derived interpretation

Sterility assurance reason.sterility_assurance · v1.0.0
Lack of sterility

These labels are deterministic app interpretations, not FDA categories.

Inspect official wording and provenance

Reason for recall

Lack of sterility assurance: resulting from use of a damaged sterilizing filter for nitrogen used in the manufacturing process.

Code information

Lot: 760853A

Distribution pattern

United States Nationwide (including Puerto Rico) and Singapore

drug · product 2 of 2

Levophed (norepinephrine bitartrate) injection, USP, 4 mg/4 mL (1mg/mL), 4mL Fill in 5 mL Single dose Fliptop Vial, Rx only, Hospira, Inc., Lake Forest, IL 60045 USA, NDC 0409-3375-04

D-1168-2017
Recall number
D-1168-2017
Initiated
August 22, 2017
Classification
Class II
Status
Terminated
Recalling firm
Pfizer Inc.
Quantity
98,050 vials

App-derived interpretation

Sterility assurance reason.sterility_assurance · v1.0.0
Lack of sterility

These labels are deterministic app interpretations, not FDA categories.

Inspect official wording and provenance

Reason for recall

Lack of sterility assurance: resulting from use of a damaged sterilizing filter for nitrogen used in the manufacturing process.

Code information

Lot #: 753003A, Exp 9/18; 762153A, 760803A, 761053A , Exp 10/18

Distribution pattern