Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 80672

1 recalled-product record grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
July 23, 2018
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
Tecan US, Inc.

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 1

Freedom EV0-2 with any version of EVOware and EVOware Sample Tracking Add-On V1.0 or higher

Z-3187-2018
Recall number
Z-3187-2018
Initiated
July 23, 2018
Classification
Class II
Status
Terminated
Recalling firm
Tecan US, Inc.
Quantity
19 EVOware Sample Tracking Software Add-on

App-derived interpretation

Device software or design reason.device_software_design · v1.0.0
software issue

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Device Design

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

There is a software issue that can potentially impact sample identification and traceability under specific conditions when using EVOware Add On Software: Sample Tracking -Multi Instrument V1.0 or higher, Part Number 30019971.

Code information

Part Numbers for Models of Freedom EVO with any version of EVOware: a. Freedom EVO 100: 10641100, 30020010, 30032010; b. Freedom EVO 150: 10641150, 10641152, 30020015, 30032015; c. Freedom EVO 200 Base Unit: 10641200, 10641202, 30020020, 30032020; Part Numbers for Software: EVOware Sample Tracking Add-On for Multi¿ Instrument Configurations: 30019971; Serial Numbers for device: 1302001540, 1708006808, 1208007284, 1503007126, 1503007304, 905000588, 1205002755, 1205002802, 1305007607, 1308005431, 1310005144, 1310005145, 905000587, 1705007973, 904000335, 1510009082, 1109004352, 1704005194, 1007000504, 1305002594, 1307006551 and 1105004439.

Distribution pattern

Nationwide distribution to CA, MA, NC, OH, TX, and VA. Worldwide distribution to Australia, Canada, China, EU, and Japan.