Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 83664

1 recalled-product record grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
August 22, 2019
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
GETINGE US SALES LLC

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 1

The HEMASHIELD PLATINUM Woven Double Velour Vascular Graft is a woven double velour polyester graft impregnated with highly purified bovine collagen. The HEMASHIELD PLATINUM Woven Double Velour Vascular Graft is designed to reduce bleeding at implant and thereby eliminates the operative preclotting step, including cumbersome autoclave techniques. The collagen is designed to be gradually resorbed by the patient. The CONCENTRICRIMP pleat and GUIDELINE stripe are also featured. In addition to collagen, the graft also contains glycerol as a softening agent.

Z-2559-2019
Recall number
Z-2559-2019
Initiated
August 22, 2019
Classification
Class II
Status
Terminated
Recalling firm
GETINGE US SALES LLC
Quantity
1 unit

App-derived interpretation

Unknown reason.no_named_rule · v1.0.0
Based on an internal incident report, Getinge/Intervascular SAS has identified that the one (1) HEMASHIELD GOLD Knitted Microvel Double Velour Vascular Bifurcated Graft product with the diameter size of 16 x 9 mm is likely incorrectly packed inside of the carton which was labeled to contain a HEMASHIELD PLATINUM Woven Double Velour Vascular Graft product with the diameter size of 16 x 8 mm ((REF: M00202166168P0, Lot: 18K31, SN: 1190443415, size 16 x 8 mm).

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Unknown

An exact joined enrichment record exists, but none supplies supported root-cause wording. This is not an FDA finding of an unknown cause.

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Based on an internal incident report, Getinge/Intervascular SAS has identified that the one (1) HEMASHIELD GOLD Knitted Microvel Double Velour Vascular Bifurcated Graft product with the diameter size of 16 x 9 mm is likely incorrectly packed inside of the carton which was labeled to contain a HEMASHIELD PLATINUM Woven Double Velour Vascular Graft product with the diameter size of 16 x 8 mm ((REF: M00202166168P0, Lot: 18K31, SN: 1190443415, size 16 x 8 mm).

Code information

Lot Code: 18K31 Serial Number: 1190443415 Part Number: M00202166168P0 UDI Code: 00384401018452

Distribution pattern

US state of NJ