Device product

Interventional Fluoroscopic X-Ray System - Philips Allura Xper Series. Labeled as the following with corresponding model numbers: 1. Allura Xper FD10, Model Number 722003. 2. Allura Xper FD10/10, Model Number 722005. 3. Allura Xper FD20, Model Number 722006. 4. Allura Xper FD20 Biplane, Model Number 722008. 5. Allura Xper FD10, Model Number 722010. 6. Allura Xper FD10/10, Model Number 722011. 7. Allura Xper FD20, Model Number 722012. 8. Allura Xper FD20 Biplane, Model Number 722013. 9. Allura Xper FD20 OR Table, Model Number 722023. 10. Allura Xper FD10, Model Number 722026. 11. Allura Xper FD10/10, Model Number 722027. 12. Allura Xper FD20, Model Number 722028. 13. Allura Xper FD20/10, Model Number 722029. 14. Allura Xper FD20 OR Table, Model Number 722035. 15. Allura Xper FD20/20, Model Number 722038. 16. Allura Xper FD20/15, Model Number 722058. 510(k) Numbers: K102005, K130842, K130638, K133292, K141979, K161563, K162859.

Z-2504-2025

August 01, 2025

Class II

Product summary

Firm
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Event
Event 97359
Status
Ongoing
Classification
Class II
Quantity
192 untis
Official record key
device-enforcement:Z-2504-2025

Official wording

Reason: Potential that a component (air baffle) may be missing in some Nehalem FlexVision-2 PCs that are part of the Allura Xper series.

Code information: 1. Model Number/System Code (UDI); Serial Numbers: 722003 (No UDI); 292, 314, 1077, 464. 2. Model Number/System Code (UDI); Serial Numbers: 722005 (No UDI); 54. 3. Model Number/System Code (UDI); Serial Numbers: 722006 (No UDI); 2126, 2200, 1560, 1921, 1724, 1219. 4. Model Number/System Code (UDI); Serial Numbers: 722008 (No UDI); 516, 142, 434, 418, 480. 5. Model Number/System Code (UDI); Serial Numbers: 722010 (00884838059030); 33, 968, 763, 215, 1425, 1126, 818, 1028, 1043, 608, 907, 50, 1390, 706, 900, 1439, 1152, 165, 62, 1031, 1088, 741, 840, 413. 6. Model Number/System Code (UDI); Serial Numbers: 722011 (00884838059047); 308, 344, 243, 266, 231, 286, 369, 378, 259, 333. 7. Model Number/System Code (UDI); Serial Numbers: 722012 (00884838059054); 2898, 2896, 1594, 1249, 2057, 2135, 2857, 792, 2841, 1334, 1550, 2868, 2912, 1094, 2282, 1681, 1332, 2032, 2076, 176, 835, 626, 1320, 1439, 1667. 8. Model Number/System Code (UDI); Serial Numbers: 722013 (00884838059061); 115, 575, 272, 632, 378, 608, 412, 353, 595, 355, 403. 9. Model Number/System Code (UDI); Serial Numbers: 722023 (00884838059085); 128, 83, 86, 134, 87. 10. Model Number/System Code (UDI); Serial Numbers: 722026 (00884838054189); 233, 561, 942, 368, 826, 1115, 539, 159, 598, 365, 528, 603, 263, 792, 783, 679, 680, 406, 388, 302, 659, 736, 1022, 22, 506, 120, 526. 11. Model Number/System Code (UDI); Serial Numbers: 722027 (00884838054196); 106, 127, 78, 204, 113, 82, 66, 119. 12. Model Number/System Code (UDI); Serial Numbers: 722028 (00884838054202); 668, 265, 1154, 180, 880, 274, 172, 1111, 806, 451, 236, 887, 874, 1266, 1499, 1514, 1457, 908, 1292, 247, 944, 951, 1390, 1662, 415, 105, 1675, 348, 1562, 1029, 51, 941, 403, 427, 659, 935, 1225, 1165, 1621, 725, 723, 1559, 753, 883. 13. Model Number/System Code (UDI); Serial Numbers: 722029 (00884838054219); 69, 58. 14. Model Number/System Code (UDI); Serial Numbers: 722035 (00884838054240); 187, 125, 40, 108, 163, 26, 75, 173, 190, 103. 15. Model Number/System Code (UDI); Serial Numbers: 722038 (00884838054226); 63. 16. Model Number/System Code (UDI); Serial Numbers: 722058 (00884838059115); 238, 161, 84, 39, 133, 244, 193, 187, 102.

Distribution pattern: Worldwide - US Nationwide distribution in the states of AL, AZ, CA, DC, FL, GA, HI, ID, IL, KS, KY, LA, MI, MN, MO, NC, NJ, NM, NV, NY, OH, OR, PA, TN, TX, UT, VA, WI, WV and the countries of Argentina, Austria, Australia, Belgium, Switzerland, Chile, China, Colombia, Czechia, Germany, Egypt, Spain, Finland, France, United Kingdom, Hong Kong, India, Italy, Japan, Korea, Republic of, Malaysia, Netherlands, Norway, Oman, Pakistan, Poland, Romania, Saudi Arabia, Sweden, Singapore, Thailand, Vietnam.

Derived failure modes

  • Unknown

    reason.no_named_rule · v1.0.0

    Potential that a component (air baffle) may be missing in some Nehalem FlexVision-2 PCs that are part of the Allura Xper series.