Skip to content
Recall Observatory FDA recall evidence

Device product

IDM-ARLITE-R. Electrical wheelchair component.

Z-2459-2025

July 10, 2025

Class I

Product summary

Firm
mo-Vis BVBA
Event
Event 97354
Status
Ongoing
Classification
Class I
Quantity
25 units
Official record key
device-enforcement:Z-2459-2025

Official wording

Reason: Devices with firmware versions 2.3 and lower may experience timing variations between software tasks, which could result in skipping the necessary neutral check and the wheelchair producing unintended movement upon power-up when the joystick is out of neutral.

Code information: Model No. PRSPS00018. UDI-DI: 05407008320102; Serial No. 1000 to 2647.

Distribution pattern: US Nationwide distribution in the state of TX.

Derived failure modes

  • Device software or design

    reason.device_software_design · v1.0.0

    firmware versions 2.3 and lower may experience timing variations between software tasks, which could result in