Skip to content
Recall Observatory FDA recall evidence

Device product

SUN|DASH RADIUS 252 tanning system; 52 lamps, Ultraviolet Radiation. The device is intended to be used for tanning of the human skin.

Z-2334-2012

July 08, 2005

Class II

Product summary

Firm
JK Products & Services, Inc
Event
Event 61869
Status
Terminated
Classification
Class II
Quantity
1948 units
Official record key
device-enforcement:Z-2334-2012

Official wording

Reason: The firm has tracked a systematic failure in the door cord on the Sun|Dash Radius 252 product line. In some instances when the door cord is installed with little or no slack outside the upper decor piece, the cord has been known to fail causing a short in the wiring at the pivot point in the cord.

Code information: PN 8000809705; Serial numbers 248-1298

Distribution pattern: Worldwide Distribution - USA (nationwide) and Canada

Derived failure modes

  • Unknown

    reason.no_named_rule · v1.0.0

    The firm has tracked a systematic failure in the door cord on the Sun|Dash Radius 252 product line. In some instances when the door cord is installed with little or no slack outside the upper decor piece, the cord has been known to fail causing a short in the wiring at the pivot point in the cord.