Skip to content
Recall Observatory FDA recall evidence

Device product

Savaria SL-1000 Stairlift

Z-2060-2017

April 12, 2017

Class II

Product summary

Firm
Savaria Concord Lifts, Inc.
Event
Event 77050
Status
Terminated
Classification
Class II
Quantity
1425 in the United States  734 in Canada
Official record key
device-enforcement:Z-2060-2017

Official wording

Reason: The electrical controller, combined with motor, causes feedback, damaging a component on the control board, starting a fire.

Code information: s/n or lot number - Job Number lots 671494 - 672668

Distribution pattern: Distribution in the United States and Canada

Derived failure modes

  • Unknown

    reason.no_named_rule · v1.0.0

    The electrical controller, combined with motor, causes feedback, damaging a component on the control board, starting a fire.