Skip to content
Recall Observatory FDA recall evidence

Device product

FULL VISION INC. TRACKMASTER,TREADMILL TMX428 220V, Model #317-07927

Z-0365-2023

August 31, 2022

Class II

Product summary

Firm
Full Vision Inc
Event
Event 90995
Status
Ongoing
Classification
Class II
Quantity
38 units
Official record key
device-enforcement:Z-0365-2023

Official wording

Reason: This has been identified a rare occurrence, under a specific scenario, where the circuit is found in a latch-up condition on the PCB that controls the safety function of the Magnetic Safety Tether, that when the magnet is pulled loose as during a fall, the treadmill may fail to stop.

Code information: UDI/DI 00860176000613, Serial Numbers: FVDC-7630, FVDC-7631, FVDC-7633, FVDC-7634, FVDC-7635, FVDC-7636, FVDC-7637, FVDC-7638, FVDC-7639, FVDC-7647, FVDC-7648, FVDC-7649, FVDC-7650, FVDC-7651, FVDC-7652, FVDC-7653, FVDC-7654, FVDC-7655, FVDC-7656, FVDC-7657, FVDC-7658, FVDC-7659, FVDC-7660, FVDC-7661, FVDC-7662, FVDC-7663, FVDC-7664, FVDC-7665, FVDC-7707, FVDC-7708, FVDC-7709, FVDC-7710, FVDC-7711, FVDC-7712, FVDC-7713, FVDC-7714, FVDC-7715, FVDC-7716

Distribution pattern: Wi, GA, NY, Mexico

Derived failure modes

  • Unknown

    reason.no_named_rule · v1.0.0

    This has been identified a rare occurrence, under a specific scenario, where the circuit is found in a latch-up condition on the PCB that controls the safety function of the Magnetic Safety Tether, that when the magnet is pulled loose as during a fall, the treadmill may fail to stop.