Device product
Medtronic Pipeline Vantage Embolization Device with Shield Technology, REF: PED3-021-350-16, PED3-021-250-14, PED3-021-350-20, PED3-021-250-20, PED3-021-300-16, PED3-021-300-20, PED3-021-275-12, PED3-021-275-16, PED3-021-325-12, PED3-021-325-14, PED3-021-325-16, PED3-021-325-20, PED3-021-250-12, PED3-021-300-14, PED3-021-250-16, PED3-021-300-12, PED3-021-275-14, PED3-021-350-14, PED3-021-350-25, PED3-021-350-12, PED3-021-250-10, PED3-021-275-20, PED3-021-350-18, PED3-021-325-18, PED3-021-275-18, PED3-021-250-18, PED3-021-300-18; and Instructions for Use, Part: M056989CDOC2
Z-1246-2025
Product summary
- Event
- Event 96168
- Status
- Ongoing
- Classification
- Class I
- Quantity
- 7820
- Official record key
device-enforcement:Z-1246-2025
Official wording
Reason: Use of embolization device with diameters greater-than-or-equal-to 4mm may lead to incomplete wall apposition and/or braid deformation (fish-mouthing/braid narrowing/braid collapse) noted during procedure and post-procedure, typically noted at 6-12 month imaging follow-up, potentially can lead to thrombosis and/or serious adverse events. Higher risk in females less-than-or-equal-to 45 years of age
Code information: Instructions for Use, Version: Rev. A (01/2024). REF/UDI-DI/Lot: PED3-021-350-16/00847536030701, 00847536035195, 00847536036529/B317460, B327449, B335184, B340948, B349032, B389162, B392918, B424454, B430015, B495821, B497938, B547396, B550307, B551615, B559033, B603377, B623564, B656863, B656887, B658904, B692346, B715057, B715058, B715541, B726894, B735821, B735823, B756029, B756030, B760210, B760211, B768202, B768387, B769453, B770633, B807494; PED3-021-250-14/00847536030411, 00847536034907, 00847536036239/B317936 B332767, B333492, B333536, B334545, B376967, B388041, B391185, B399354, B416713, B431395, B452416, B457963, B467691, B476239, B564173, B564970, B574472, B580923, B629372, B630998, B670305, B673035, B699576, B707568, B709193, B736698, B736893, B739090, B739091, B795110, B796586, B800827, B801770; PED3-021-350-20/00847536030725, 00847536035218, 00847536036543/B319436, B336571, B379993, B383427, B389708, B400103, B400599, B403612, B407062, B415211, B446722, B483987, B490972, B492403, B494049, B552487, B559741, B591782, B591864, B592074, B622656, B626023, B648708, B684905, B715692, B719565, B719567, B719659, B726923, B728926, B735667, B756330, B765053, B768231, B770237, B770248, B792630; PED3-021-250-20/00847536030442, 00847536034938, 00847536036260/B321465, B337378, B360749, B371070, B412868, B467843, B477487, B488713, B548244, B557602, B644034, B673388, B679822, B684208, B686727, B695486, B698571, B703035, B708080, B709204, B711078, B746067, B757056, B757060, B761030, B771498, B775215, B789892, B790055; PED3-021-300-16/00847536030541, 00847536035034, 00847536036369/B321725, B338497, B405720, B418200, B570723, B574473, B603375, B604477, B656277, B658580, B659806, B666425, B681289, B691752, B699606, B703209, B707982, B711365, B725679, B736659, B738114, B769551, B769582, B798864; PED3-021-300-20/00847536030565, 00847536035058, 00847536036383/B322263, B336066, B347327, B376257, B405892, B414535, B458672, B458776, B469040, B490920, B495292, B563197, B607500, B607501, B635214, B636992, B656299, B656355, B657960, B668529, B678482, B680045, B681190, B712110, B712111, B718522, B720923, B725457, B732895, B735956, B737156, B737367, B748272, B748683, B749541, B775230, B778774, B780044; PED3-021-275-12/00847536030466, 00847536034952, 00847536036284/B323044, B383016, B391275, B399486, B454385, B468406, B623580, B623583, B624424, B657776, B666498, B669520, B670179, B670226, B710976, B743820, B743822, B754659, B762034, B768199, B798851; PED3-021-275-16/00847536030480, 00847536034976, 00847536036307/B323046, B361987, B406342, B414102, B458076, B468915, B477868, B558538, B562688, B563304, B603078, B654235, B656399, B657059, B666486, B669610,B670343, B677246, B699308, B736874, B743098, B755194, B755196, B755673, B769461, B771317, B775167, B775168; PED3-021-325-12/00847536030602, 00847536035096, 00847536036420/B324297, B407597, B418843, B494876, B561787, B592073, B623579, B629046, B676507, B678997, B716220, B741395, B751748, B787015, B787017; PED3-021-325-14/00847536030619, 00847536035102, 00847536036437/B324809, B347993, B362685, B459598, B558177, B563209, B575964, B580901, B628946, B675724, B678948, B681904, B714342, B714344, B733352, B733353, B769593, B790478; PED3-021-325-16/00847536030626, 00847536035119, 00847536036444/B324954, B339033, B371691, B418451, B460439, B495941, B603378, B604475, B623578, B624422, B660509, B664402, B666503, B667510, B667920, B668523, B680717, B681747, B733912, B739722, B739723, B739724, B746618, B794191, B794192; PED3-021-325-20/00847536030640, 00847536035133, 00847536036468/B325613, B371743, B418905, B421650, B463895, B487451, B495368, B591952, B591955, B644630, B644769, B644809, B657857, B659135, B659138, B659243, B684852, B716733, B716735, B741305, B741316, B741321, B787131; PED3-021-250-12/00847536030404, 00847536034891, 00847536036222/B326236, B335270, B387931, B390988, B394283, B421249, B477292, B497244, B578963, B664457, B666521, B667945, B669726, B696189, B719158, B724199, B724200, B724764, B741102, B746521, B764797, B764798, B787764, B787765, B787766, B793905; PED3-021-300-14/00847536030534, 00847536035027, 00847536036352/B327828, B335957, B346789, B393640, B399293, B403772, B456576, B547554, B568649, B575299, B631125, B631126, B649258, B650123, B652886, B657773, B683152, B711496, B712157, B712158, B732804, B732807, B754755, B754756, B754757, B760951, B760953, B768142, B769947, B789256; PED3-021-250-16/00847536030428, 00847536034914, 00847536036246/B328095, B416673, B452284, B478579, B494048, B565441, B573470, B575302, B628868, B628869, B630965, B656206, B666535, B667323, B668743, B739139, B739405, B739408, B754155, B754886, B754888, B755651, B794406, B794408, B794426; PED3-021-300-12/00847536030527, 00847536035010, 00847536036345/B338969, B345449, B346121, B361988, B405158, B418358, B454923, B551608, B561782, B562698, B563303, B575894, B677108, B677319, B699289, B703245, B718483, B718491, B739905, B744728, B760716, B766588; PED3-021-275-14/00847536030473, 00847536034969, 00847536036291/B343142, B361366, B379727, B429213, B448933, B452378, B461124, B601345, B607550, B624425, B626121, B678023, B680119, B711192, B713287, B724745, B744169, B744175, B744176, B770971, B770988; PED3-021-350-14/00847536030695, 00847536035188, 00847536036512/B349031, B372357, B388981, B391924, B399969, B421758, B445867, B491603, B492310, B497318, B596593, B629649, B630549, B631109, B670495, B678371, B679957, B713023, B713796, B740630, B740631, B742526, B743935, B753618; PED3-021-350-25/00847536030732, 00847536035225, 00847536036550/B364361, B393438, B403082, B419021, B422233, B430531, B437842, B447224, B488266, B616574, B624414, B629444, B629660, B672265, B672892, B673364, B717131, B717132, B724110, B733587, B733590, B741976, B761681, B768780, B771211, B772034, B773456, B773457; PED3-021-350-12/00847536030688, 00847536035171, 00847536036505/B368529, B406425, B419491, B490325, B496666, B497114, B611908, B615889, B616569, B643508, B643509, B644619, B657109, B658427, B659171, B690687, B715610, B715612, B716621, B742378, B746455, B787264; PED3-021-250-10/00847536030398, 00847536036215, 00847536034884/B387475, B390553, B427939, B490270, B575123, B578342, B628755, B654233, B666402, B670376, B693553, B707945, B711113, B740699, B764024, B764025, B766116, B769419, B797931, B801945; PED3-021-275-20/00847536030503, 00847536034990, 00847536036321/B391792, B398628, B418296, B452832, B461730, B497830, B548241, B567772, B655966, B656945, B666505, B671729, B677211, B679094, B680758, B693403, B699179, B711385, B725638, B725639, B736012, B736612, B737225, B751998, B756411, B797986; PED3-021-350-18/00847536036536/B798906; PED3-021-325-18/00847536036451/B800239; PED3-021-275-18/00847536036314/B805162; PED3-021-250-18/00847536036253/B805488; PED3-021-300-18/00847536036376/B807417
Distribution pattern: Worldwide distribution: US (nationwide): PR, OK, CA, MD, FL, NY, WA, MI, AL, NV, MN, NJ, IL, OH, AK, CT, TN, MO, TX, ID, AZ, WI, PA, OR, SD, VA, CO, GA, KY, IN, AR, MA, LA, NE, MT, ME, SC, DC, NC, ND, NM, IA, UT, KS, WV, NH, HI, RI. And OUS (foreign) countries of: Algeria, Argentina, Armenia, Australia, Austria, Bahrain, Bangladesh, Belgium, Brazil, Bulgaria, Canada, Canary Islands, Chile, Colombia, Costa Rica, Croatia, Cyprus, Czech Republic, Denmark, Dominican Republic, Ecuador, Egypt, Finland, France, Germany, Greece, Hong Kong, Hungary, Iceland, India, Ireland, Israel, Italy, Jordan, Kazakhstan, Kuwait, Latvia, Lebanon, Lithuania, Luxembourg, Malaysia, Martinique, Mexico, Republic Of Moldova, Montenegro, Morocco, Netherlands, New Zealand, North Macedonia, Northern Ireland, Norway, Panama, Peru, Philippines, Poland, Portugal, Qatar, Reunion, Romania, Russia, Saudi Arabia, Serbia, Singapore, Slovakia, South Africa, South Korea, Spain, Sweden, Switzerland, Taiwan, Thailand, Tunisia, Turkey, Ukraine, United Arab Emirates, United Kingdom, Uruguay, Vietnam
Derived failure modes
-
Unknown
Use of embolization device with diameters greater-than-or-equal-to 4mm may lead to incomplete wall apposition and/or braid deformation (fish-mouthing/braid narrowing/braid collapse) noted during procedure and post-procedure, typically noted at 6-12 month imaging follow-up, potentially can lead to thrombosis and/or serious adverse events. Higher risk in females less-than-or-equal-to 45 years of age